Basic informations

 

Version 5.0 of the "RemoteHMI Menu" for the Thin Clients series 5x6, 5x7 and 5x8 controls all configuration data directly via the menu.

 

The following features were implemented with Version 5.0:

Automatic scaling of the menu to fit the screen size (always the same size action fields)

Support of several Ethernet interfaces

Simultaneous connection of Thin Client with several Remote PCs -> fast change of displayed Remote PC

Active monitoring of status of established connection

Support of several screens of the  Remote PC

Display in portrait mode

3-level access management for action fields (buttons) of the "RemoteHMI Menu"

Installation of applications (apps)

 

Other features adopted from Version 4.0 include:

Establishing of RDP and / or VNC connections

Specification of fallback connections

in order to ensure access to the Remote PC in case of failure of the active connection

Touch calibration of the Thin Client

Activation of right mouse-click for the touch (simulation of the right mouse key)

Touchscreen lock for cleaning purposes

Screen brightness adjustment

 

 

Btn_Top10x10 Topics:

 

 

1.1 Connection principle:

 

For devices of series 5x6

Thin-Clients-EAGLE-(SERIES-5x6)

 

For devices of series 5x7

Thin-Clients-MANTA-(SERIES-5x7)

 

For devices of series 5x8

Thin-Clients-SHARK-(SERIES-5x8)

 

 

1.2 Display via VNC:

 

As a standard, the video output of the server is displayed in full at the maximum possible size whilst maintaining the correct aspect ratio. Non-native resolutions may result in black horizontal or vertical margins.

Server resolutions (much) greater than the native Thin Client display resolution will also be fully displayed, but small structures will be the harder to recognise, the greater the difference to the native Thin Client resolution.

 

 

1.3 Display via RDP:

 

As a default, the connected server always starts a session with the native resolution of the Thin Client.

 

 

1.4 RemoteHMI Menu:

 

The "RemoteHMI Menu" is located on the right hand side of the Thin Client.

You can open and close it by pressing F(unction key) 8.

 

Menu with status "no Remote connection":

Fgr_StartUpMenu

Menu header with title

"Address Book" register.

Configured connections in the address book

Placeholders for more connection buttons

(Number depending on active device type and number of configured connections)

Buttons for (device settings )

 

Information fields,




Status second interface (if existing)




Status first interface




Access level

 

Click on Fgr_OpnDetails in the menu header to display further details and registers.

 

Click on Fgr_OpnConfig to get to the settings modus (changers require engineer or admin authority).

 

Symb_ExtKaptlExpand device settings

 

1.5 Extended Menu:

 

The RemoteHMI menu contains the following registers and buttons.

 

Mnu_Registers

1

2

3

4

5

6

7

 

1)Button to minimize detailed view of the "Address Book" register

2)Change to "Dashboard" register

3)Change to "Address Book" register (the one currently shown)

4)Changes to "Applications" register

5)Chnages to "Network" register

6)Changes to "Settings" register

7)Button for closing the RemoteHMI menu

 

 

1.6 Status line (fields):

 

Status field

Meaning

Fgr_BtnUsrState

Field showing user status. This is where the current user level is shown.

Three user levels are currently available: operator, engineer and admin.

Fgr_BtnEthrntEstblsh

First Ethernet interface with "connected" status.

There is an exchange of Ethernet frames.

This is an Ethernet connection

and can be used to set up a Remote connection,

provided the Remote PC has an active server for the connection that is to be established (VNC RDP).

Fgr_BtnEthrntFailed

Second Ethernet interface with "not connected" status

No Ethernet connection could be established. The physical (OSI layer 1) or the Ethernet protocol level (OSI layer 2) cannot be established.

The connection cannot be used to establish a Remote connection.

All Remote connections that require this connection cannot be established.

Fgr_StFld_Wifi

Status field for a wireless WiFi interface. Not active (ready) here.

 

Detailed information on:

Kapitelseite RemoteHMI-Menu

 

 

1.7 Installation of the factory software:

 

If you need to re-install the factory software, proceed as follows:

 

In safe area:

 

Switch off the device.

If required, open the back cover.

Stick the USB stick with the factory software into the X4 USB socket  (5x6 u. 5x8 only) or into the socket of the VB-USB-Plug cable.

Switch on the device.

The factory software will now be installed automatically.

 

In hazardous area  (xT-xx6 Series only):

 

Switch off the device.

Stick the intrinsically safe USBi stick with the factory software into the socket of the VB-USB-Plug cable which may be located on the outside of the device.

Switch on the device.

The factory software will now be installed automatically.

 

 

Once the installation has been completed, switch the device back off.

 

Hinweis

Please remove the USB stick before restarting the device, since otherwise the device would expect an installation of the factory software when being re-booted.

 

 