Structure of key bits in the peripheral input of the process data area

Auswahl Hilfen previous top next english version

Easy ProfibusEPB Functional DescriptionProcess data areaPeripheral input key field 1

 

In the peripheral input key field 1 you will find information about the functional keys of the operator interface that have been pressed.

Each time a function key is pressed, the corresponding key bit is set and remains set for the entire time the function key remains pressed.

Please not that due to the cycle times there might be a delay in setting and resetting these bits.

 

Peripheral input
Key field 1



Start address +00

Key

valid for

Bit 00

F01

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 01

F02

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 02

F03

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 03

F04

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 04

F05

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 05

F06

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 06

F07

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 07

F08

ET-65, ET-75, ET-125

MT-65, MT-125

Bit 08

F09

ET-65, ET-125

MT-65, MT-125

Bit 09

F10

ET-65, ET-125

MT-65, MT-125

Bit 10

F11

ET-65, ET-125

MT-65, MT-125

Bit 11

F12

ET-65, ET-125

MT-65, MT-125

Bit 12

F13

ET-65, ET-125

MT-65, MT-125

Bit 13

F14

ET-65, ET-125

MT-65, MT-125

Bit 14

F15

ET-65, ET-125

MT-65, MT-125

Bit 15

F16

ET-65, ET-125

MT-65, MT-125

 

Notes:

- The combination (pressing) of several function keys at the same time is not supported. All key bits will be = 0 (zero) in that case.

- In the EasyProfibus no key bits are allocated to the key combinations Shift+F-key, ALT+F-key and CTRL+F-key.

- In the EasyProfibus no key bits are allocated to the soft keys .

 

 