Mechanical

Vorheriges Oben Nächstes Helps selection copy topic address english version

AccessoriesTrackballInstallationMechanical

 

 

If the TBi-50-PS2 trackball has NOT been factory mounted, a sufficiently large cut-out and a hole pattern for mounting the trackball must be provided.

 

Make a cut-out with the following dimensions: 152 (±1) mm (height) x 90 (±1) mm (width).

Drill 10 holes of a diameter of 3.5 mm according to the hole pattern.

Mount the trackball inside the cut-out and use the self-locking nuts (10x M3) provided to affix the trackball.

 

 

Optimum sealing:

 

Tighten the nuts lightly.

Check the position of the trackball, ensuring above all that the rubber seals are correctly positioned.

Now fully tighten the nuts.

 

Warnhinweis

IP65 is only guaranteed when the trackball is not in operation.

In that case, IP is reduced to IP54.

 

Please note that any water that may be on the trackball could enter the inside of the trackball enclosure when the trackball is being operated, and might cause damage.

 

Connect the trackball cable to the X9 terminal at the HMI according to the connection diagram.

 

Warnhinweis

The TBi-50-PS2 trackball housing must be earthed via the equipotential bonding connection (earthing screw) at the back of the housing.

The wire used must have a minimum cross section of 4mm² !

 

 

Further Informations:

Kapitelseite View

Klicken Sie hier um untergeordnete Kapitel anzuzeigen bzw. geöffnete zu schließen. Dimensions

 

See also:

Klicken Sie hier um untergeordnete Kapitel anzuzeigen bzw. geöffnete zu schließen. Electrical

 

<< back