Installation

Vorheriges Oben Nächstes Helps selection copy topic address english version

AccessoriesReadersSK-300Installation

 

 

The scanner's base station transfers the data to the connected interface as soon as they have been received, without requiring any flow control. Because of this, the data transmission only requires a connection to the HMI.

 

The voltage supply of the base station varies according to which version (DC or AC) is used. Please note the details and type plates on the base station.

 

The reader interface parameters (default settings) of the BCSi-SK-300-RSST barcode scanner are:

7 data bits

1 stop bit

even parity

9600 baud

 

Please make sure that these reader interface parameters match the settings of the software that receives the scanner data.

If this is not the case, you need to change them.

 

**

Hinweis

Please also always refer to the BCSi-SK-300 card reader documentation issued by the reader's manufacturer.

 

 

Terminal assignments at the base station:

BS 300 base station

Connection (terminal)

Definition


DC version

AC version

1

+

L

2

+

N

3

PE (Protective earth)

4

PS2: data / USB: D+, green

5

PS2: clock / USB: D-, white

6

PS2: GND / USB: GND

7

RS-232: TxD

8

RS-232: GND

9

RS-485: A

10

RS-485: B (and one side of the terminating resistor)

11

RS-485: Terminating resistor, if necessary, connected with pin 9

12

Connection NOT permitted!

 

 

Further information:

Kapitelseite Basisstation an RS-232

Klicken Sie hier um untergeordnete Kapitel anzuzeigen bzw. geöffnete zu schließen. Basisstation an RS-485

Kapitelseite Maßskizze

 

See also:

Kapitelseite Technical Data

Kapitelseite Standards and Directives

 

 

<< back