Click to expand or collaps information.   Connecting to ET/MT-xx6-...

The RS232 interface of the devices is provided at terminals 9-13 at the X2 and X3 terminal blocks. The interface is a type DTE interface. The signals have the following meaning:

 

Pin

Name

Definition

9

TxD

Data/Out - the data is sent from here.

10

RxD

Data/In, this is where the data is received.

11

RTS

Request to send, transmission request from DTE to DCE, Signals to the DCE that the DTE wishes to send data

12

CTS

Clear to send, DCE ready to receive. ready to receive. Signals that the DCE can receive data from the DTE.

13

GND

Ground, equipotential bonding

 

BCSi-SK-300

Base station


COM1/COM2 (X2/X3)

Terminals

RS_232_ConPinning

 

*

Hinweis

The voltage supply of the base station varies according to which version (DC or AC) is used. Please note the details and type plates on the base station.

 