Connection to RS232

Vorheriges Oben Nächstes Helps selection copy topic address english version

AccessoriesReadersRFIDi-RDR... (Ex)Electrical InstallationConnection to RS232

 

RFID_Connect_To_RS232

 

For the exact pin configuration at the target device please refer to the documentation issued by the manufacturer. Please note the type (DTE or DCE) of the interface.

 

 

Hinweis

A 12 VDC power supply is required to operate a chipcard reader.

 

Click to expand or collaps information.  Connecting to ET/MT-xx6-...

Figure be following show the connecting of the xx6 series.

 

RFIDI-RDR2-MIF-xx Reader

 

ET - / MT - xx6, X8

Modul ET-READER-2

Fgr_RFIDi_Con_To_xx6HwRev3

 

Terminal RFID(i) - Reader

Signal

Typical colour of wire

Terminal ET - / MT - xx6

1

VDC

Brown

0

2

GND

White

3

3

 

.-.

 

4

 

.-.

 

5

RxD

Yellow

6

6

 

.-.

 

7

TxD

Green

5

 

Typical configuration: 9600 / 8 / 1 / Parity none

 

See also:

Kapitelseite Connectors ET / MT-xx6

 

RFIDi_Connect_To_HwRev2

See also:

Kapitelseite Connectors ET / MT-xx6

 

 

Click to expand or collaps information.  Connecting to ET/MT-xx7-...

Figure be following show the connecting of the xx7 series via the reader box.

 

Connecting_RFIDi_to_xx7

 

A

Select the Readerbox according to the connection voltage of the xT-xx7 (AC or DC).

 

Hinweis

For  the terminal box to be installed in hazardous areas it must be certified for operation in the actual hazardous zone !

 

See also:

Kapitelseite Connectors ET/MT-xx7

 

 