Accessories ► ReaderBox ► Electrical installation ► X1 Power supply connection general

|
Warning
|
Explosion hazard, when connecting device in hazardous area !
|
If you have to connect the device in a hazardous area
you must use a suitable explosion-protected terminal box !
(for example a series 8118 terminal box).
|
|
24 VDC Class II

|
The output circuit cable is about 1.1 metres long and typically 3 x 1 mm² !
|
Wire
|
Signal name
|
Definition
|
1
|
+ VDC
|
Supply voltage 24VDC+
|
2
|
GND
|
Supply voltage ground 0VDC
|
Green/yellow
|
|
Equipotential bonding
|
|
See also:
24VDC from ET / MT - xx6, Anschlussbeschreibung der 24VDC - Variante an die Geräte der xx6 Serie
100 bis 240 VAC powerline

|
The output circuit cable is about 1.1 metres long and typically 3 x 1 mm² !
|
Wire
|
Signal name
|
Definition
|
1
|
L1
|
Supply voltage phase
|
2
|
N
|
Supply voltage neutral
|
PE
|
Earth
|
Protective earth
|

|
Re. *1),
Make sure you have the AC version
before connecting the ReaderBox to the mains !
|
|
|
See also:
Connectors ReaderBox
24VDC of ET / MT - xx6
Connection RS232 to ET/MT-xx6
Connection RS232 to ET/MT-xx7
Connection RS422 to ET/MT-xx6
<< back
|