Warnhinweis

Explosion hazard due to electrostatic charge / discharge!

1.The keyboard must be grounded with at least 4mm².

2.Generally, the keyboard is designed for mobile use, which necessitates a flexible earth connection preventing the wires from breaking.

3.If there is no or insufficient earth connection the keyboard must not be operated in a hazardous area.

 

Warnhinweis

The keyboard has a conductive coating to prevent electrostatic

charges / discharges.

 

If the conductive coating is damaged the keyboard must be removed from the hazardous area.

 

Click to expand or collaps information.  Connection of USB Variant:

The following table shows the connection of the USB keyboard to devices of R.Stahl HMI.

 

PIN

Keyboard cable

Operator

Interface

Panel PC

Thin Client

Wire

Colour

Signal name

Meaning

1

red

VCC

Supply +

2

white

D-

Data minus

3

black

D+

Data plus

4

schwarz

GND

Supply

mass

ET/MT-3x6

X6

ET/MT-4x6

X6

ET/MT-4x7

X11,12

ET/MT-5x6

X6

ET/MT-5x7

X11,12

1

1

1

1

1

2

2

2

2

2

3

3

3

3

3

4

 

4

4

4

4

 

Click to expand or collaps information.  Connection of PS2 Variant:

The connection of a PS2 keyboard to the devices of R. STAHL HMI Systems GmbH is shown in the following table.

Keyboard cable

PIN

Operator

Interface

Panel PC

Thin Client

Wire

Colour

Signal name

Meaning

1

yellow

VCC

Supply +

2

brown

DATA

Data

3

white

CLK

Clock

4

green

GND

Supply

mass

5

black

SHIELD

Cable shield

ET/MT-3x6

X9

ET/MT-4x6

X9

ET/MT-5x6

X9

1

1

1

2

2

2

3

3

3

6

 

6

6

PE

PE

PE

 