AccessoriesPower supply DSPq-120-24Electrical installationConnect mains power

 

Warnhinweis

Warning

Explosion hazard, when connecting device in hazardous area !

If you have to connect the device in a hazardous area

you must use a suitable explosion-protected terminal box !

(for example a series 8118 terminal box).

 

Wire

Colour

Signal name

Definition

1

Brown

L1 or +VDC

Mains power Phase or +VDC

2

Blue

Neutral or Ground

Mains power Neutral or VDC - Ground

PE

Green/yellow

Earth

Protective earth

 

Fgr_DSPs_ConDetailed2

L1 or + VDC (Brown)

N or VDC Ground (Blue)

PE protective earth  (yellow/Green)


 

The power supplies are delivered together with a terminal box type 8112 for connection to the mains.

Klemmenkasten_8118

Klemmenkasten_8118_2

 

The terminals in the terminal box are marked as in the description above. Allocation is according to the marking.

The terminal box should ideally be connected to the mains via the screw connection at the top.

The power supply can be connected via the two screw connections at the bottom.

 

Hinweis

The terminals of the terminal box are intended for the connection of two devices to the mains.

 