Ethernet Connection information

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesKVM-Systems, ET/MT-6x8...Electrical InstallationEthernet Connection information

 

The ET/MT-6x8 devices can be ordered with a copper-based Ethernet connection Below is a description of the different versions:

 

Copper:

 

Cables connected to the Ethernet terminals (X5) must have a minimum cross section of 0.2 mm² (metric) (AWG 24).

Which cable cross sections are chosen should be decided on the basis of relevant regulations, such as DIN VDE 0298 . Factors that might require a larger cross section, such as current, increased temperatures, cable bundling, etc. must also be taken into account. Factors that might require a larger cross section, such as current, increased temperatures, cable bundling, etc. must also be taken into account.

 

Click to expand or collaps object. Connection diagram:

 

X2_X3_EthernetPort

Table Ethernet cable colours:

 

100Base-TX:

MT/ET-4x8-TX

MT/ET-5x8-TX

 

Coding according by

X2 / X3 Pin

Function

VB-TP-CAT5-Exe-R45-Patch

EIA/TIA-T568A

EIA/TIA-T568B

1

TxD +

Yellow

Orange / White

Green / White

2

TxD -

Orange

Orange

Green

3

RxD +

White

Green / White

Orange / White

4

RxD -

Blue

Green

Orange

 

Table Ethernet cable colours:

 

1000Base-TX:

MT/ET-6x8-TX

 


X2 / X3 Pin

Funktion

EIA/TIA-T568A

EIA/TIA-T568B

1

D1+ / TxD +

Orange / White

Green / White

2

D1- / TxD -

Orange

Green

3

D2+ / RxD +

Green / White

Orange / White

4

D2- / RxD -

Green

Orange

5

D3 +

Bluw / White

6

D3 -

Blue

7

D4 +

Brown / White

8

D4 -

Brown

 

Click to expand or collaps object.  Colour coding Ethernet, T568A und T568B:

EthernetkabelFarbcodierung

 

Connection cable for 100Base-TX:

Cable colour codingVB-TP-CAT5-Exe-RJ45-Patch:

 

Yellow

blue

White

Orange

 

Profinetkabel

 

For more information, please refer to chapter (VB-TP-CAT5-Exe-RJ45-Patch ) of the cable descriptions.

 

 

cable type:


1000Base-T

Twisted Pair cable at least 8 x 2 x 0.4-0.6 rigid or 8 x 2 x 0.27 - 0.5 flexible, recommended type: Cat-5 or above.

100Base-TX

Twisted Pair cable at least 4 x 2 x 0.4-0.6 rigid or 4 x 2 x 0.27 - 0.5 flexible, recommended type: Cat-5 or above.

 

See also:

X2 and X3
Ethernet
BtnSymbol

 

 