IDM160 Barcode scanner via RS-232

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesPanel PC, ET / MT 4x8...Electrical InstallationConnection ofConnection of accessoriesIDM160 Barcode scanner via RS-232

 

Hand-held device:

The wired handheld scanner is connected to the VB-IDM160-XX6-RS232-SR-* connection cable by inserting the RJ45 plug into the corresponding socket until you can hear a "click". Then check that the cable is firmly connected.

 

Fgr_Hand_Scanner_IDM160

 

Pin assignment:

 

 

Cable to scanner

Device name

Binder plug

Cable

Position

3

4

Definition

VB-IDM160-XX6-RS232-SR-...

View

Fgr_Plug_3_PE

Assignments / connections (wire / pin)

Pin

Signal

1

+UB

2

GND

3

TxD

4

-

-

-

 

Bluetooth base station:

Hinweis

Before screwing the base loading station onto the (field) enclosure, the VB-IDM160-Base-RSi-RS232-SR-*.8m-Z1 connection cable must be inserted into the opening on the underside of the base loading station.

 

1.The plug must engage audibly.

2.Clamp the connection cable into the cable bushing.

 

Fgr_Wireless_Scanner_IDM160

 

Pin assignment:

 

 

Cable to scanner

Device name

Binder plug

Cable

Position

1

2

Definition

VB-IDM160-XX6-RS232-SR-...

View

Fgr_Plug_3_PE

Assignments / connections (wire / pin)

Pin

Signal

1

+UB

2

GND

3

TxD

4

-

-

-

 

Hinweis

Devices who are ordered with the "IDM160" option have the connection socket positioned on a connection plate ex-factory.

 

The power supply is connected to the 408-series devices at terminals 2 and 3 of X32.

 

Fgr_Ex-i_ConX32_to_IDM160

 

 

Installation:

Figure cover enclosure:

Fgr_ConnectorFields

Fgr_CableFixPoint_1

Frg_CableFixPoint_2

Frg_CableFixPoint_Shield

Fgr_CableFixPoint_3

Frg_CableIntoGland

 

*1)

Select a screw terminal that provides the shortest distance to the connection!

Make sure that other connections do not cross!

*1)

Select a screw connection that tightly encloses and seals the cable!

 

*1 & 2

Unscrew the retaining screws of the cable fixation at the cable holder.

3a

Unscrew the screws of the cable fixation of the screw connection as far as necessary.

3b

Unscrew the lower part of the screw connection.

3c

Slide the cable fixation of the screw connection over the cable.

3d

Slide the cable through the sealing sleeve.

The sealing sleeve can remain inside the screw connection.

3e

Slide the cable through the screw connection at the cover.

4

Strip the insulation from the cable down to the required length.

In the case of shielded cables, unbraid the braided shield.

Pull the braided shield over the cable so that it can later fit into the cable holder (4.1).

4a

Strip 7-10mm insulation of the required cable.

Crimp core end sleeves onto the individual wires.

4b

Terminate the individual cables at the plug according to the above terminal assignment.

5a

Screw the cable holder onto the plate of the connections.

5b

Insert the plug into the terminal connector of the connection.

5c

Use the screws to fix the plug to the terminal connector.

5d

Screw the cable fixation with inserted cable onto the cable holder.

If there is a shield, place this between cable and cable fixation.

Make sure the shield maintains a secure contact to the cable fixation.

5e

Pull back the cable so that the insulation extends past the cable fixation by at least 6 mm.

Make sure the wires are not taut and can be moved freely.

 

 

 

Cover mounting:

 

1. Guide the cover towards the cover enclosure.

 

2. Pull back the cables until they lie tension-free inside the cover enclosure.

3. Screw the cover onto the cover enclosure.

 

4. Slide the sealing sleeves of the screw connections into the screw connections at the cover.

 

5. Screw the lower part of the screw connections into the screw connections at the cover enclosure.

Tighten the screw.

 

6. Check that the cables fit firmly inside the screw connection.

 

7. Tighten the screws of the cable fixation to ensure the cables are not subject to tensile stress.

Check that the cables fit firmly inside the screw connection.

 

 

 

<< back