Connections table:

Terminal

Pin

Meaning

Connection

X1

1

Supply voltage +24V DC

Power supply

2

Supply voltage +24V DC

3

Power supply GND

4

Power supply GND

X2 *1

1

TxD-b

COM1 serial interface

RS-422/RS-485

2

TxD-a

3

RxD-b

4

RxD-a

5

TxD-b'

6

TxD-a'

7

RxD-b'

8

RxD-a'

9

TxD > Output

COM1 RS-232 serial DTE interface

10

RxD < Input

11

RTS > Output

12

CTS < Input

13

GND

X3 *1

1

TxD-b

COM2 serial interface

RS-422/RS-485

2

TxD-a

3

RxD-b

4

RxD-a

5

TxD-b'

6

TxD-a'

7

RxD-b'

8

RxD-a'

9

TxD > Output

COM2 RS-232 serial DTE interface

10

RxD < Input

11

RTS > Output

12

CTS < Input

13

GND

X4

 

USB interface, connection type A

USB0 Ex-i

X5

1

VCC

USB1 Ex-e

2

USB -

3

USB +

4

GND

X6

1

VCC

USB2 Ex-i

2

USB -

3

USB +

4

GND

5

GND (from Rev. 1 onwards)

X7

1

VCC

USB3 Ex-e

2

USB -

3

USB +

4

GND

 

*1)

Option, have to be ordered.

 

Hinweis

Please note that the COM interface may only be physically connected once!

Interconnection is provided either with a physical RS-232

or an RS-422/485 connection.

 

Hinweis

USB connections USB0 and USB2 as well as USB1 and USB3 are wired in parallel. The USB connections USB0 and USB2 as well as USB1 and USB3 must therefore not be used at the same time !

 