VB-BC-3

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesEagle ET/MT-3x6...Connection ofCableVB-BC-3

 

The VB-BC-3 cable is used to connect the BCSi-SK200-RSST barcode scanner to the device variants RSi and RSi1.

The flanged connector is installed inside the field housing of the device, and the "open" cable end is connected to terminal X8 of the device.

 

The connection cable VB-BC-3 (1.0m) is included in the scope of delivery of the devices for the RSi variants.

 

View VB-BC-3:

 

VB-BC-3-Kabel

 

 

Hinweis

Contacts 1, 4 and 5 of the flanged connector are not occupied.

 

Connection details VB-BC-3:

 

Fgr_VB_BC_3_Pinning

 

Standard cable assignment

PIN

Signal

colour

2

RxD

yellow

3

TxD

green

6

+5V

brown

PE

PE / GND

white

 

 