RFIDi - Leser via RS-232

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesEagle ET/MT-3x6...Connection ofReadersRFIDi - Leser via RS-232

 

Click to expand or collaps object.        Figure, Connection HW-Rev. 3

RFIDI-RDR2-MIF-xx Reader

 

ET - / MT - xx6, X8

Modul ET-READER-2

Fgr_RFIDi_Con_To_xx6HwRev3

 

Terminal RFID(i) - Reader

Signal

Typical colour of wire

Terminal ET - / MT - xx6

1

VDC

Brown

0

2

GND

White

3

3

 

.-.

 

4

 

.-.

 

5

RxD

Yellow

6

6

 

.-.

 

7

TxD

Green

5

 

Typical configuration: 9600 / 8 / 1 / Parity none

 

Click to expand or collaps object.        Figure, Connection HW-Rev. 2

RFIDI-RDR2-MIF-xx Reader

 

ET - / MT - xx6, X8

Modul ET-READER-1

Fgr_RFIDi_Con_To_xx6HwRev2

 

Terminal RFID(i) - Reader

Signal

Typical colour of wire

Terminal ET - / MT - xx6

1

VDC

Brown

9

a bridge between 0 and 2 is necessary

2

GND

White

3

3

 

.-.

 

4

 

.-.

 

5

RxD

Yellow

6

6

 

.-.

 

7

TxD

Green

5

 

Typical configuration: 9600 / 8 / 1 / Parity none

 

See also:

Kapitelseite Connections ET/MT-3x6

 

Hinweis

When ordering the ET-/MT-3x6 for application in field systems (installation inside an 8150 enclosure), the RFID reader can be ordered as an extra option.

 

In this case, the ET-/MT-3x6 and the RFID reader are firmly installed inside the 8150 enclosure.

 

 