Barcodescanner IDM160 via RS-422

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesEagle ET/MT-3x6...Connection ofReadersBarcodescanner IDM160 via RS-422

 

Handheld:

The wired handheld scanner is connected to the VB-IDM160-XX6-RS232-SR-* connection cable by inserting the RJ45 plug into the corresponding socket until you can hear a "click". Then check that the cable is firmly connected.

 

Fgr_Hand_Scanner_IDM160

 

Pin assignment:

 

 

Cable to scanner

Device name

Binder plug

Cable

Position

3

4

Definition

VB-IDM160-XX6-RS232-SR-...

View

Fgr_Plug_3_PE

Assignments / connections (wire / pin)

Pin

Signal

1

+UB

2

GND

3

TxD

4

-

-

-

 

Base loading station:

Hinweis

Before screwing the base loading station onto the (field) enclosure, the VB-IDM160-Base-RSi-RS232-SR-*.8m-Z1 connection cable must be inserted into the opening on the underside of the base loading station.

 

1.The plug must engage audibly.

2.Clamp the connection cable into the cable bushing.

 

Fgr_Wireless_Scanner_IDM160

 

Pin assignment:

 

 

Cable to scanner

Device name

Binder plug

Cable

Position

1

2

Definition

VB-IDM160-XX6-RS232-SR-...

View

Fgr_Plug_3_PE

Assignments / connections (wire / pin)

Pin

Signal

1

+UB

2

GND

3

TxD

4

-

-

-

 

Hinweis

For field systems ordered with option “IDM160“, the connector  is led through by means of a screw connection installed ex-factory.

 

ReaderBox X3:

Fgr_BinderSocket_to_ReaderBox

 

 

Connection to the flange

Device name

ReaderBox-054-DC-RS232

data circuit

Binder fixed socket

Position

1

2

Definition

open cable end X3

IDM160-Socket-3+PE

View

Fgr_ReaderBox_X3_Cable

Fgr_Socke_3_PE

Assignments / connections (wire / pin)

Wire

Signal

Pin

Signal

 

+ VDC

1

+UB

 

GND

2

GND

 

RxD

3

TxD

 

TxD *

4

-

Green / yellow

Not used **

-

-

 

*

the wire 4 of the X3 data circuit of the ReaderBox is not needed and must be cut off at the cable end !

**

This wire was cut off ex-factory and is not assigned in the ReaderBox !

When the data cable is shortened, this wire must also be cut off again.

 

Inside junction box of the ET / MT-xx6:

ReaderBox_To_xx6_RS422

 

RS-422 connection detail:

 

ReaderBox_To_xx6_RS422detail

 

 

Device name

ReaderBox-...-DC(AC)*1

Connection

Data circuit

Cable

5 x 1 mm²

-

Designation

Open cable end X2

Terminal X2 (COM1 - RS-232)

View

Fgr_ReaderBox_X3_Cable

delivery state:

all wires black and numbered..

Fgr_xx6_X2_connector

Assignments / connections

(wire / pin)

Wire

Signal

Pin

Signal

3

Black

RxD-b

1

TxD-b

4

Grey

RxD-a

2

TxD-a

1

Brown

TxD-b

3

RxD-b

2

Blue

TxD-a

4

RxD-a

5

Green / Yellow

Not used

-

-

 

*1)

DC = ReaderBox with 24 VDC connection.

AC = ReaderBox with 100 to 240 VAC connection.

 

 

Inside junction box of the ET / MT-xx6:

ReaderBox_To_xx6

 

Detail of the 24VDC connection:

ReaderBox_To_xx6_detail

 

 

Device name

ReaderBox-054-DC-RS232

HMI ET-/MT-xx6

Connection

Power supply

Cable

3 x 1 mm²

-

Designation

Open cable endX1

Terminal X1 (VDC)

View

Fgr_X1_cable_pinout

Fgr_xx6_X1_connector

Assignments / connections (wire / pin)

Wire

Signal

Pin

Signal

-

-

-

1

+24 VDC

1


+ VDC

2

+24 VDC

-

-

-

3

GND

2


GND

4

GND

PE

Green / yellow

Earth

PE

Equipotential bonding connection

 

 

If the X1 terminals are already being used by the optional hard disk, the power supply must be connected in an Ex-certified terminal box outside of the HMI..

 

If there is no internal hard disk and other devices are to be supplied with 24 VDC, the optional X12 terminal block can be used to distribute the supply voltage.

 

24VDC at X12 terminal block:

X12_VDC_Expand

HMI 24VDC power supply

ReaderBox X1

 

Hinweis

Because Ex-e and Ex-i signal circuits must not be connected at the same time, any free terminals may only have Ex-e signal circuits connected !

 