Ambient temperatures / mounting method

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesKVM-Systems, ET/MT-6x8...Assembly ET- / MT - 6x8 DevicesAmbient temperatures / mounting method

 

Hinweis

The storage temperature is not affected by the installation described as follow.

 

SERIEs xx8 Derating of Ambient Temperatures for different installations.

 

Symb_Caution1_30x30

Attention

The influence of direct sunlight to the maximum ambient temperature (HTC/HTF) might be important

and we suggest to protect the unit against direct sunlight.

 

The lower ambient temperature (LTC/LTF) might be affected by wind.

 

*1)

LTC -        Lower ambient temperature in °C

-40°

C for units with optional internal heater

+10°

C without heater

LTF -        Lower ambient temperature in °F

-40°

F for units with optional internal heater

+14°

F without heater

 

Below tables define the derating of the maximum ambient temperature (HTC / HTF) for different installations:

 

Display orientation

Inclination

Description

Ambient Temperature *1

Fgr_LandscpInst

 

Fgr_LndscpSdVw90

Vertical 90°

Landscape horizontal 90 °

standing free

HTC=+65° C

HTF=+149° F

 

 

Fgr_LandscpInst

Fgr_LndscpSdVw45

Vertical 45°

Landscape horizontal 45 °

standing free

HTC=+60° C

HTF=140° F

 

Fgr_LandscpInst

Fgr_LndscpSdVw

Vertical 0°

Landscape horizontal 90 °

standing free

minimum 10cm gap

below device

HTC=+60° C

HTF=+140° F

 

Fgr_PotraitInst

Fgr_VerticalInst

vertikal 90°

Portrait vertical 90 °

standing free

HTC=+60° C

HTF=+140° F

Fgr_PotraitInst

Fgr_Vert90Inst

vertikal 45°

Portrait vertical 45 °

standing free

HTC=+60° C

HTF=+140° F

Fgr_LandscapeInclInst

Fgr_LandscapeEnclInst

Landscape,

installation in enclosure, inclination independent

HTC=+50° C

HTF=+122° F

 

Fgr_PotraitInclInst

Fgr_PotriatInclInst

Portrait,

installation in enclosure,

inclination independend

HTC=+50° C

HTF=+122° F

 

 

 

<< back