Assembly bracket

Vorheriges Oben Nächstes Helps selection copy topic address english version

HMIs, human machine interfacesET-208AssemblyAssembly to operating panelAssembly bracket

 

Hinweis

The Assembly bracket is vital for ensuring stability and tightness of the mounted device.

 

Ensure you leave sufficient cicon2 Installation space for the ET-208!

 

Mount the device using all provided fasteners and the assembly bracket:

 

The assembly bracket MUST be used to ensure the safe and correct installation of the operator interface.

A suitable assembly bracket with 8 fasteners is available for the enclosure.

Fix the brackets in the corresponding gaps of the fixing groove.

 

Optimum sealing:

 

Tighten the screws lightly.

Check the position of the device, ensuring above all that the entire operator interface is correctly positioned.

Now tighten the screws of the fasteners with a tightening torque of between 7,5 and 8,5 Nm.

 

Warnhinweis

To maintain protection type IP 65, please ensure the following:

The device was mounted by an expert on a plain and smooth surface.

 

Tension-free assembly:

 

Below is an example of how the individual screws of the mounting brackets can be tightened for a tension-free assembly of the display. The main thing is to tighten the screws in a rotating sequence, moving from the centre towards the edges.

 

Example: Sequence :

Fixierrahmen_2x8_Srewing

 

 

Ideally, the screws should at first only be tightened slightly and, at the second rotation, be tightened fast.

 

 